ISO 10478:1994

Current Revision
Petroleum products - Determination of aluminium and silicon in fuel oils - Inductively coupled plasma emission and atomic absorption spectroscopy methods

Best Price Guarantee en - English 1 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00
View in Library
or
International Organization for Standardization Logo

Petroleum products - Determination of aluminium and silicon in fuel oils - Inductively coupled plasma emission and atomic absorption spectroscopy methods

The principle of the method specified is heating a weighed quantity of homogenized sample in a clean platinum basin, removing the combustible material by burning, finally removing the carbon by heating, fusing the residue with a dilithium tetraborate/lithium fluoride flux, digesting the fused mixture in a solution of tartaric acid and hydrochloric acid, dilution to volume with water, measuring the solution by ICPES or AAS. The method is applicable for concentrations between 5 mg/kg and 150 mg/kg for aluminium and 10 mg/kg and 250 mg/kg for silicon.

Loading...

Failed to load document history.

Publish Date Document Id Type View