IEEE C57.12.10-2017

IEEE Standard Requirements for Liquid-Immersed Power Transformers

PUBLISH DATE 2018
PAGES 55
Document Preview
Revision Standard - Active. This voluntary consensus standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, liquid-immersed power transformers and autotransformers. Such power transformers may be remotely or integrally associated with either primary switchgear or substations, or both, for step-down or step-up purposes and base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase.This standard applies to all liquid-immersed power transformers and autotransformers that do not belong to the following types of apparatus: instrument transformers, step voltage and induction voltage regulators, arc-furnace transformers, rectifier transformers, specialty transformers, grounding transformers, mobile transformers, and mine transformers.
This voluntary consensus standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, liquid-immersed power transformers and autotransformers. Such power transformers may be remotely or integrally associated with either primary switchgear or substations, or both, for step-down or step-up purposes and base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase. This standard applies to all liquid-immersed power transformers and autotransformers that do not belong to the following types of apparatus: a) Instrument transformers b) Step voltage and induction voltage regulators c) Arc-furnace transformers d) Rectifier transformers e) Specialty transformers f) Grounding transformers g) Mobile transformers h) Mine transformers
SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C57.12.10
Publication Date April 27, 2018
Language en - English
Page Count 55
Revision Level
Supercedes
Committee Transformers
Publish Date Document Id Type View
April 27, 2018 C57.12.10-2017 Revision