1.1 This test method covers the determination by filtration time after cold soak of the suitability for a biodiesel (B100) blend stock that meets all other requirements of Specification D6751 and has a cloud point below 20°C (68°F) to provide adequate low temperature operability performance to at least the cloud point of the finished blend.
5.1Â Some substances that are soluble or appear to be soluble in biodiesel (B100) at room temperature will, upon cooling to temperatures above the cloud point or standing at room temperature for extended periods, come out of solution. This phenomenon has been observed in both B100 and BXX blends. These substances can cause filter plugging. This method provides an accelerated means of assessing the presence of these substances in B100 and their propensity to plug filters.
| SDO | ASTM: ASTM International |
| Document Number | D7501 |
| Publication Date | Nov. 1, 2012 |
| Language | en - English |
| Page Count | 6 |
| Revision Level | 12a |
| Supercedes | |
| Committee | D02.14 |